CIRCUIT BREAKER
 |
| |
| |
|
Technical
characteristics |
|
The Italfarad
Circuit Breaker is a device connected to the running capacitor of a
single phase electric motor that provides an extra help when starting,
staying connected for a very short time with an additional starting
capacitor.
It replaces
the old starting methods like the centrifugal one, cumbersome and
wearisome in fitting up.
The Italfarad
Circuit Breaker is largely adopted for several applications like
electric motors for air compressors, washing machines, pumps and
generally for all those applications in which the motor is supposed to
overcome a considerable opposite mechanical torque.
Currently
there are 3 models: 2 electromechanical (ITF04 and ITF06) and 1
electronic (ITF02). |
|
|
ITF04 Series |
|
Motor supply voltage |
100 ÷ 220 Vac |
|
Frequency |
50/60 Hz |
|
Climatic category |
-25°C +70°C |
|
Voltage range on C*
run |
130 ÷ 450 Vac |
|
Operating time |
1,2 sec. |
|
Restarting time |
6 sec. |
|
Starting capacitance |
from 0 to 85 µF |
|
Dimensions |
from 0 to 40 µF 55 x 94 mm
from 41 to 85 µF
55 x 118 mm |
|
*C run: running
capacitor |
|
Single-phase
electric motor 100
÷ 220 Vac |
|
(Vmin on C run 130
Vac - Vmax on C run 450 Vac) |
|
|
ITF06 Series |
|
Motor supply voltage |
220 ÷ 240 Vac |
|
Frequency |
50/60 Hz |
|
Climatic category |
-25°C +70°C |
|
Voltage range on C*
run |
320 ÷ 480 Vac |
|
Operating time |
1,2 sec. |
|
Restarting time |
6 sec. |
|
Starting capacitance |
from 0 to 85 µF |
|
Dimensions |
from 0 to 40 µF 55 x 94 mm
from 41 to 85 µF
55 x 118 mm |
|
*C run: running
capacitor |
|
Single-phase
electric motor 220
÷ 240 Vac |
|
(Vmin on C run 320
Vac - Vmax on C run 480 Vac) |
|
|
ITF02 Series |
|
Motor supply voltage on
request |
110 Vac or 230 Vac |
|
Frequency |
50/60 Hz |
|
Climatic category |
-25°C +85°C |
|
Voltage range on C*
run |
0 ÷ 550 Vac |
|
Operating time |
0,75 sec. |
|
Restarting time |
4 sec. |
|
Starting capacitance |
from 0 to 150 µF |
|
Dimensions |
from
0 to 40 µF 55 x 94 mm
from 41 to
85 µF 55 x 118 mm
from 86 to
100 µF 60 x 118 mm
from 101 to 150 µF
65 x 118 mm |
|
*C run: running
capacitor |
|
Single-phase
electric motor 110 Vac or 230 Vac |
|
(Vmin on C run 0
Vac - Vmax on C run 550 Vac) |
| Additional
connection "SINGLE PHASE SUPPLY) |
| |
|
Electromechanical Circuit Breaker
ITF04 - ITF06 |
|

|
|
Electronic Circuit Breaker
ITF02 |
 |
| |
|
On Customer's request,
Italfarad makes circuit breakers with special execution
The
manufacturer reserves the right to modify data and sizes without
previous. notice. |